6BChapter 7: Controlling a PTZ camera
48 TruVision DVR 60 User Manual
To configure PTZ dome camera settings:
1. Enter the PTZ Settings screen by selecting PTZ in the main menu.
2. In the Camera box, select the PTZ dome camera to be configured from the
drop-down list.
3. Select the baud rate, data bit, stop bit, parity and flow control for the camera.
The default values are:
Baud rate: 9600
Data bits: 8
Stop bits: 1
Parity: None
Flow control: None
Note: Click the Default button to return all values to default settings.
4. When all changes have been made, click the OK button to save the changes
and return to the main menu.
Assigning PTZ protocols
Assign a PTZ protocol and address to a camera to allow PTZ control of the
camera while in PTZ mode. See Appendix C “PTZ protocols” on page 135 for the
complete list of available protocols. The default protocol is GE RS-485.
To configure PTZ settings:
1. Enter the PTZ Settings screen by selecting PTZ in the main menu.
2. In the Camera box, select the PTZ dome camera to be configured from the
drop-down list.
3. Select a PTZ protocol in the PTZ protocol box.
4. Enter the PTZ address. Up to three digits can be entered. The number should
correspond with that used in the PTZ dome camera itself.
5. When all changes have been made, click the OK button to save the changes
and return to the main menu.
Copying settings to other cameras
PTZ dome camera settings can be copied to other PTZ dome cameras
connected to the DVR. In the Copy To option of the PTZ menu, select a
particular camera, or all cameras. Click Copy.